General
• Dimensions/Weight: 238×163×h 250 mm/4 kg
• Trace: 6 waveform (ECGx2, SpO2, RR or EtCO2 IBPx2)
• Indicators: categorized alarms (3 priority levels), visual alarm lamp handle, QRS beep, SpO2 pulse beep, heart rate, SpO2 pulse pitch tone battery status, external power LED
• Thermal printer: 25, 50 mm/sec (paper width 58 mm)
• Battery: Rechargeable Li-ion (3 hours operating time)
• Interfaces: LAN digital output for transferring data Nurse call system connection defibrillator sync. output
• DC input connector:18 VDC, 2.8A max
• Operating voltage: 100-240 V, 50-60 Hz
SpO2
• % Saturation Range: 0% to 100% ±2 digits (70 to 100%)
• Pulse Rate Range: 30 to 254 bpm ±2 bpm
ECG
• Lead type: 3-lead, 5-lead
• Lead selection: 3-lead: I, II, III
• ECG Waveforms:
3-lead 1 channel
5-lead: 1/2/7 channels
• Heart rate range:
Adult: 30-300 bpm
Neonate/pediatric: 30-350 bpm
• Heart rate accuracy: ± 1 bpm or ± 1%, wichever is greater
• Sweep speed: 6.25, 12.5, 25, 50 mm/sec.
• Filter:
Diagnoses: 0.05 to 150 Hz
Monitoring 0.5 to 40 Hz
Moderate: 0.5 to 25 Hz
Maximum: 5 to 25 Hz
• S-T Segment detection range: - 2.0 to 2.0 mV
• Arrhythmia analysis: Asystole, Vtach, Vfib, Bigeminy, Accvent Couplet, Irregular, Pause, Pvc, Ront, Trigeminy, Vbrady, Shortrun
• Pacemaker detection mode: Indicator on waveform display (user selectable)
• Protecion: against electrosurgical interference and defibrillation
NIBP
• Technique: Oscillometric with linear deflation
• Pressure range: 0 to 300 mmHg ± 3 mmHg
• Measurement Modes: Manual-Automatic-Continuous
• Safety pressure:
Adult: 300 mmHg
Neonate: 150 mmHg
• Measurement range:
Adult pressure: 20 to 260 mmHg
Pediatric pressure: 20 to 160 mmHg
Neonate pressure: 20 to 130 mmHg
Pulse rate: 30-220 bpm
• Accuracy: meets accuracy requirements of ANSI/AAMI ISO 81060-2-2013
Respirations
• Range: 5 to 120 breaths/min ±1 b/min
• Apnea alarm: yes
Temperature Unit (optional )
• Range: 0° to 50°C (32°F to 122°F)
• Accuracy: ± 0.1°C (25 to 50°C), ± 0.2°C (0 to 24°C)
• Compatible with: YSI Series 400 Temperature Probes
IBP - (option not included)
• Channels: 2
• Measuring range: -50 to 300 mmHg
• Measuring accuracy: ± 1 mmHg (<100 mmHg) ± 1 % of reading(>100 mmHg)
• Pulse rate counting range: 0 to 300 beats/min
• Zero balancing:
range ± 200 mmHg
accuracy ± 1 mmHg
drift ± 1 mmHg over 24 hours
• Transducer sensitivity: 5µV/V mmHg
EtCO2 - Respironics (option not included)
• Measurement mode: Sidestream or Mainstream
• Measurement range: 0~150 mmHg, 0 to 19%
• Respiration range: 2~150 bpm
• Accuracy:
± 2 mmHg, 0~40 mmHg
± 5%, 41~70 mmHg
± 8%, 71~100 mmHg
± 10%, 101~150 mmHg
• Respiration accuracy: ± 1 breath per minute