The ECG Mini Cardio B, usable for a regular heart check, is an ideal solution for costantly check health and for those people that suffer cardiovascular deaseses like hypertension, diabete, etc.
It recognises and provides 17 different interpretations:
1 - no irregularity
2 - suspect of slightly accelerated beat
3 - suspect of accelerated beat
4 - suspect of short cycle accelerated beat
5 - suspect of slightly slowed beat
6 - suspect of slowed beat
7 - suspect of irregular short beat interval
8 - suspect interval of irregular beats
9 - suspect accelerated beat with short interval
10 - suspect of slowed beat with short beat interval
11 - suspect of slowed beat with irregular beat interval
12 - Arrhythmia
13 - suspect of accelerated beat with arrhythmia
14 - suspect of slowed beat with arrhythmia
15 - suspect of occasional slowed beat interval with arrhythmia
16 - suspect of irregular beat interval with arrhythmia
17 - low signal, please make new test
Main features:
• ECG waves and results are showed on a high resolution LCD display
• Can save 14 Mb of data
• Automatic switch off after 35 second of no use
• Works with 2 AAA batteries: up to 500 record
Measurement methods
Thoracic
1. In order to have best ECG waves, thoracic measurement is suggested.
2. Hold the device in the right hand. Be sure that palm and fingers perfectly touch the metallic electrodes I and II.
3. Put the electrod III on the naked sking about 5 cm under the left nipple. The signal received by the device is similar to the V ECG derivation signal
Leg
When isn't possible use the thoracic measurement, the leg measurement is suggested.
1. During the measurement, hold the device in the right hand.
2. Be sure that palm and fingers perfectly touch the metallic electrodes I and II.
3. Put the electrod III on the skin about 10 cm above the left ankle. The signal received by the ECG is similar to the II ECG derivation signal
Palm
1. Hold the device in the right hand.
2. Be sure that palm and fingers perfectly touch the electrodes I and II.
3. Press the electrod III against the center of the left palm. The signal received by the ECG is similar to the I ECG derivation signal.
Cables
For a better ECG, is possible to use the measurement with the connection cable
1. Connect the cable to the device using the relative plug
2. Put the electrodes and connect them to the cables as showed in the user manual to get II ECG derivation signal; if you wish to get the I and II ECG derivation signals, connect the cables to the electrodes as showed in the user manual.